<pre id="kapvl"></pre>
        1. <dfn id="kapvl"></dfn>

          1. Vacuum pressure reducing concentrator-HUBEI JINBANG LIGHT INDUSTRIAL AND MACHINERY CO.LTD

            Product

            Position:Home > Product > Core Equipment > Concentration Evaporation Series

            Vacuum pressure reducing concentrator

            Product Introduction:

            Vacuum feeding is used for addition, so when using, the vacuum pump should be turned on and the feeding valve should be opened at the same time. In order to ensure a certain evaporation space, the liquid level in the tank should be close to the cylinder sight glass. After closing the feeding valve, the jacket steam valve can be opened to allow the liquid in the tank to boil moderately and start evaporating. In order to accelerate the speed, vacuum concentration is adopted, and the vacuum degree is determined by the user's different requirements.

            Hotline: 027-88161243
            Consultation Back
            Product Description

            Vacuum pressure reducing concentrator

            Working principle of vacuum concentration tank

            IMG_256

            Vacuum feeding is used for addition, so when using, the vacuum pump should be turned on and the feeding valve should be opened at the same time. In order to ensure a certain evaporation space, the liquid level in the tank should be close to the cylinder sight glass. After closing the feeding valve, the jacket steam valve can be opened to allow the liquid in the tank to boil moderately and start evaporating. In order to accelerate the speed, vacuum concentration is adopted, and the vacuum degree is determined by the user's different requirements.


            The operation can be divided into two types: continuous and intermittent. If the pressure reducing process is used for continuous feeding, a flow meter should be installed on the feeding pipeline to control the feeding amount. The flow range depends on the size of the concentration tank container. The feeding height should not exceed the cylinder sight glass for the liquid section inside the tank. But currently, many pharmaceutical factories tend to operate with gaps, which is relatively simple and inefficient, but more convenient to operate. Discharge can only be carried out after the tank returns to normal pressure, so it is intermittent discharge.


            The principle of this equipment to achieve concentration is relatively simple, that is, the extract is heated to boil, the water is evaporated, and the foam with effective ingredients in the evaporated secondary steam is separated from the vapor liquid separator in the reflux cylinder to avoid waste. The evaporation intensity is generally 50~60. Due to the structure limitation and easy cleaning, the specific gravity of the concentrated solution should not be greater than 1.2~1.25kg/m2h, otherwise, feeding and cleaning will bring some difficulties.

            IMG_256

            Technical Parameter

             Specification/Model

            ZN-50

            ZN-100

            ZN-200

            ZN-300

            ZN-500

            ZN-700

            ZN-1000

             Volume (L)

            50

            100

            200

            BOO

            500

            700

            1000

             Receiving tank (L)

            35

            45

            60

            76

            100

            125

            165

             Jacket pressure (Mpa)

            0.09

            0.09

            0.09

            0.09

            0.09

            0.09

            0.09

             Vacuum degree (mmHg)

            600-700

            600-700

            600-700

            600-700

            600-700

            600-700

            600-700

             Heating area (m²)

            0.25

            0.59

            0.8

            1.1

            1.45

            1.8

            2.2

            Condensation area (m²)

            1.2

            1.7

            2.4

            3.0

            3.3

            3.6

            4.1

            Cooling area (m²)

            0.29

            0.35

            0.45

            0.6

            0.7

            0.85

            1.05

            Dimensions (mm)

            長(L)

            1200

            1350

            1700

            1700

            2100

            2400

            2390

            寬(W)

            600

            750

            800

            1000

            1200

            1300

            1300

            高(H)

            2200

            2200

            2700

            3400

            3400

            3400

            3720

            Consult
            QQ
            Telphone
            027-88161243
            We Chat
            To Top